Type 1700S Telephone Analyzer |
| Type 1700S |
Main Functions |
![]() |
Can test the electrical characteristics of an analogue corded and cordless phone, PBX and the transformer : The tested items varies according to different country standard, Like : Frequency Response and Loudness Rating of the receiving、sending and Sidetone, Harmonic Distortion, Return Loss, DCR, Loop Current, DC I-V, I-R, ON-HOOK Leakage Current, ON HOOK AC Impedance Curve , OFF HOOK AC Impedance Curve, Linearity or Amplitude response , Clipping Test , the Sensitivity and Frequency Response Curve of the H.A.C. Magnetic Field … etc. Provide Softwares for > 30 National Stds. with the corresponding Artificial Line |
| Catalogue pdf File |
Main Features Test Items Accredited Example of Test Screen
1700 Set Up Combination Specifications Optional Functions
|
The fundamental combination of Type 1700S Go Back |
|||
|
Item |
Model No. |
Description |
Usage |
|
1. |
170 S |
Telephone Analyzer |
Mainframe. To control and process the input、output signal. |
|
2. |
Monitor & Keyboard |
High Resolution Color Display Monitor & Keyboard |
Display the tested results & data and key in data. User may buy these two items at his local market, since price is cheaper and can save freight charge and import tax. |
|
3. |
147B |
Test Head |
Sets the test angle and position of the artificial ear and mouth, to test the acoustic characteristics of the handset. |
|
4. |
140M |
Artificial Mouth |
Generates a flat and stable、precise sound field, for testing the “Transmitter". |
|
5. |
142EA-S4 |
Artificial Ear ( 142EA-S4 = IEC - 318 ) |
Receives the sound generated from the receive. |
|
6. |
173 XXX (or 163 XXX) |
Artificial Line ( 173 XXX ) or Terminator ( 163 XXX ) |
The artificial line in accordance to the specified country standard from the Telecom to the client ‘s site. ( Country Standard press here ) |
|
7. |
Hearing Protection & R. Noise Measurement Set |
Combine for use with the Model-170A mainframe , to test the characteristic for the hearing protection and receiving residual noise of the telephone. ( See " Note " please ) |
|
|
9. |
X-Y Mouse |
Mouse |
Replace the upward, downward, leftward, rightward and enter keys on the keyboard. |
|
10. |
HP Printer ( Option) |
Printer (All the HP DeskJet or HP Laser Printers that are supported by DOS can all be used.) |
Print out the tested results & data. |
|
Note : GM-2 is used for testing the hearing protection and receiving residual noise , Some countries like Germany, England, Australia and New Zealand etc. required this kind of testing, If not require the testing for the hearing protection and receiving residual noise , then, GM-2 is not needed. |
|||
|
### Functions and Specifications of Type 1700S Go Back
|
|
### Optional Functions : Go Back Type 1700 can test the PBX 、 PABX、Modem、 Receiver、 Transmitter、 ECM 、Transformer for Communication:
(a) With an
optional
Model-172A , when combined with
Type 1700, can test various
characteristics of PBX、PABX、Modem,
including the Insertion
Loss、
Cross
Talk (-40
∼
-110dB)、Distortion、Return
Loss、Impedance、Frequency
Response、
I-V Curves、
I-R Curves, High Test Speed.
(b) With an
optional
Model-167
, when combined with Type 1700, can
test the
Receiver、Transmitter、Frequency
Response of ECM、Impedance、Distortortion、Sensitivity、H.A.C.
Magnetic Field of Receiver, High Test speed. (c) With an optional Model-174 , when combined with Type 1700, can test the Frequency Response、Distortion、 Insertion Loss、Return Loss of theTransformer for Communication, also, user can test the above-mentioned various characteristics under the condition of DC current setting from 0 to 120 mA, High Test Speed. (d) With an optional Model-154F , Complies with U.S.A EIA RS 504 standard. When combined with Type 1700, can test the axial、radial magnetic field intensities and their freq. response curves of the telephone or the receiver unit.
|