Features :                                        Catalogue  (pdf File)           Go Back

  DC Resistance and AC Impedance testable.

  Built-in adjustable signal generator 20 Hz 8 kHz, external frequency input is available.

  Upper / Lower limits  can be set.  Very fast judging  the  PASS / FAIL. Two LCD display impedance & freq., 152A can be used as a stand alone freq. counter. 

Used for testing the impedance and resistance of the receiverloudspeakerheadphone ... etc., auto judging PASS / FAIL , can be used also as a frequency counter.

Electroacoustic  component  has  different impedance under different  frequency,  needs  to set a suitable frequency to test the rated  impedance  of such  component.  152A contains :  a 20Hz ~ 8kHz signal generator, two LCD display frequency & impedance.  Upper / Lower  limits can be set.  Very fast in auto judging the PASS/FAIL, suitable for 100% Q.C. in production line. 152A suits for the loudspeakerheadphonereceiver firms, also suitable for incoming  inspection of the audiomonitor &  multimedia  firms.

 

Specifications  of  Model - 152A

  1. Impedance / Resistance Range :

  1. 0 Ω 120 Ω, Resolution 0.1 Ω

  2. 120 Ω 4000 Ω, Resolution 1 Ω

  1. Signal Generator : 20Hz ~ 8 kHz , adjustable.

  2. Tolerance :

  1. 1 kHz Zx : ≦ ± ( 0.4 % 0.1 Ω ).

  2. Zx ( 20 Hz 20 kHz ):≦ ± ( 0.8% 0.1Ω).

  3. DCR : ≦ ± ( 0.2 % 0.1 Ω ) .

    4.    Frequency Counter : 10 Hz    100 kHz.

    5.    Dim. : 36 ( L ) × 13 ( H ) × 28 ( D ) cm.

    6.    Net Weight : 4.5 KGS.