Type 1600F Anechoic Chamber Free Loudspeaker Test System |
| Type 1600 F |
Main Functions |
![]() |
The following items of loudspeaker can be
measured
: (1) Frequency response (2) Sound pressure sensitivity at 1 kHz (1 kHz can be changed) (3) Average sensitivity of sound pressure within a frequency range (4) Polarity (5) DC Resistance (DCR) (6) AC Impedance (ACZ) (7) Distortion at 6 points (8) Fo (9) Qe (10) Qt (11) Qm (12) Automatic PASS/FAIL judgment of above items (1) to (8) (13) Curve of distortion against frequency (14) Curve of distortion against SPL (15) Curve of AC impedance. Note : Type 1600F can test the Loudspeaker Unit only. |
| Catalogue pdf File |
Combination Specifications Example of Testing Screen
Technical knowledge 1600F Set Up Program Down Load Go Back
|
The fundamental combination of Type 1600 F Go Back |
|||
|
Item |
Model No. |
Description | Usage |
|
1. |
160 A |
Electroacoustic Analyzer |
Mainframe. To control and process the input、output signal. |
|
2. |
Monitor & Keyboard |
High Resolution Color Display Monitor & Keyboard |
Display the tested results & data and key in data. User may buy these two items at his local market, since price is cheaper and can save freight charge and import tax. |
|
3. |
171 |
Electroacoustic Testing Adapter |
Combines with 160A mainframe, to test the freq. response curve、 sensitivity、 impedance、 Fo、 polarity、 distortion 、 parameter etc. of the loudspeaker 、 headphone 、speaker box. |
|
4. |
8120HF |
Measuring Microphone |
Its frequency response curve is very flat、precise and stable, can test the freq. response curve and sensitivity of the loudspeaker, or can be used as a feedback microphone. |
| 5. |
143B |
Test Box |
Combines with 160A and 171 mainframe, the freq. response curve、 sensitivity、 distortion curve of the loudspeaker can then be tested even without an anechoic chamber , test result is the same as the one done in a standard anechoic chamber using a JIS test box. |
|
6. |
X-Y Mouse |
Mouse |
Replace the upward, downward, leftward, rightward and enter keys on the keyboard. |
| 7. |
HP Printer ( Option ) |
Printer (All the HP DeskJet or HP Laser Printers that are supported by DOS can all be used.) |
Print out the tested results & data. |
|
About specifications , Please refer to the specifications of Type 1600 S Go Back |
|
Speed
for testing one loudspeaker of Type 1600F :
When full automatic test mode is
chosen, only 5.9 seconds are required for testing the all 11 item
(listed below), including the display of all measured results and the
judgment of PASS/FAIL (1/12 Oct, 20 Hz to 20 kHz). Note: 5.9 seconds
is only a typical value, in fact, its test speed is related to the Fo
value of the under testing loudspeaker and the tested width band.
Automatically and continuously
testing: (1) Frequency response; (2) Sound pressure sensitivity at 1
kHz (1 kHz can be changed); (3) Average sensitivity of sound pressure
within a frequency range; (4) Fo; (5) Polarity; (6) DC
Resistance (DCR); (7) AC Impedance (ACZ); (8) Qm; (9) Qe; (10)
Qt; (11) Automatic judgment of PASS/FAIL of above items 1 to 7. ★The frequency response and distortion of a loudspeaker measured and printed out by 1600F are the same as those measured according to JIS or CNS standard in a large anechoic chamber. |